Radar Amplifiers (cont.)
Traveling Wave Tubes, Klystrons, CFA’s, Magnetrons and Cavity Oscillators/Amplifiers
1.5 TO 5 kW CW KLYSTRON AMPLIFIERS: MOD-ANODE BLANKING
Model KCWP1000C
1.5 kW CW, 6.95 - 7.0 GHz, Band Width: 20 MHz @ -1 dB Mod Anode controlled for blanking
Model KCWP1000C
2.5 kW CW, 6.9 - 7.1 GHz, Band Width: 20 MHz @ -1 dB Mod Anode controlled for blanking
Model KCWP1000X
5 kW, 9.95 - 10.5 GHz, Band Width: 50 MHz @ -1 dB
35 TO 500 WATT DUAL MODE - BOTH GRID PULSED AND CW TWTA’s
Model 37
35 to 70 Watts, Frequencies 2.0 - 6.0 or 8.0 GHz, 6.0 or 8.0 - 18.0 GHz Grid Pulsed or CW, PRF to 1 MHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW operation
Model 267
40 Watts, Frequencies 18.0 - 26.5 and 26.5 - 40.0 GHz, Grid Pulsed or CW, PRF to 100 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW operation
Model 267
125 Watts, Frequencies 18.0 - 26.5and 26.5 - 40.0 GHz, Grid Pulsed or CW, PRF to 100 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW operation
Model 267Q
100 Watts, Frequencies 40 to 45 GHz, Grid Pulsed or CW, PRF to 100 kHz, Pulse Width 50 nanoseconds to CW, Duty cycle up to 50%, PRF to 100 kHz
Model 267
35 Watts, Frequencies 18.0 - 40.0 GHz, Grid Pulsed or CW, PRF to 100 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW
Model 367
200 Watts, Frequencies 1.0 - 18.0 GHz, Grid Pulsed or CW Operation, PRF to 500 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW
250 Watts, Frequencies 1.0 - 2.5 GHz, PRF to 200 kHz
250 Watts, Frequencies 2.5 - 7.5 GHz, PRF to 200 kHz
250 Watts, Frequencies 7.5 - 18.0 GHz, PRF to 200 kHz
250 Watts, Frequencies 1.0 - 2.0 GHz, PRF to 200 kHz
250 Watts, Frequencies 2.0 - 4.0 GHz, PRF to 200 kHz
250 Watts, Frequencies 4.0 - 8.0 GHz, PRF to 200 kHz
250 Watts, Frequencies 8.0 - 18.0 GHz, PRF to 200 kHz
Model 567
500 Watts, Frequencies 1.0 - 18.0 GHz, Grid Pulsed or CW Operation, PRF to 500 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50% pulsed or CW
500 Watts, Frequencies 1.0 - 2.5 GHz, PRF to 200 kHz
500 Watts, Frequencies 2.5 - 7.5 GHz, PRF to 200 kHz
500 Watts, Frequencies 7.5 - 18.0 GHz, PRF to 200 kHz
500 Watts, Frequencies 1.0 - 2.0 GHz, PRF to 200 kHz
500 Watts, Frequencies 2.0 - 4.0 GHz, PRF to 200 kHz
500 Watts, Frequencies 4.0 - 8.0 GHz, PRF to 200kHz
Model 67
50 Watts, Frequency 92 - 96 GHz, Grid Pulsed or CW Operation, PRF to 200 kHz, Pulse Width 50 nanoseconds to CW, Duty Cycle up to 50%
CONTINUOUS WAVE TWTA’s
Model 20C/Ku
Frequency 4.0 - 18.0 GHz, 20 Watts CW
Model 100S/C
Frequency 2.0 - 8.0 GHz, 60 Watts CW
Model 100C/Ku
Frequency 4.5 - 18.0 GHz, 67 Watts CW
Model 100C/Ku
Frequency 6.0 - 18.0 GHz, 55 Watts CW
Model 200L
Frequency 1.0 - 2.0 GHz, 250 Watts CW
Model 200L/S
Frequency 0.8 - 2.5 GHz, 250 Watts CW
Model 200S
Frequency 2.0 - 4.0 GHz, 250 Watts CW
Model 200S/C
Frequency 2.0 - 8.0 GHz, 200 Watts CW
Model 200S/C
Frequency 2.5 - 7.5 GHz, 250 Watts CW
Model 200C
Frequency 4.0 - 8.0 GHz, 250 Watts CW
Model 200C/Ku
Frequency 6.0 - 18.0 GHz, 250 Watts CW
Model 200C/Ku
Frequency 7.5 - 18 GHz, 250 Watts CW
Model 200X
Frequency 8.0 - 12.4 GHz, 250 Watts CW
Model 200X
Frequency 8.0 to 12.0 GHz, 1,000 Watts CW
Model 200X/Ku
Frequency 8.0 - 18.0 GHz, 250 Watts CW
Model 200Ku
Frequency 12.4 - 18.0 GHz, 250 Watts CW
Model 200K
Frequency 17.0 - 21.7 GHz, 200 Watts CW
Model 400K
Frequency 17.7 - 22.0 GHz, 450 Watts CW